| Part number |
ES-001 |
ESF-002 |
ESF-003A |
ESF- 005 |
ENF- 005 |
| Rated voltage |
250 VAC |
250 VAC |
250 VAC |
250 VAC |
| Rated current |
1 A |
2 A |
3 A |
5 A |
| DC resistance |
0.9 Ω max |
0.3 Ω max |
0.15 Ω max |
0.1 Ω max |
| Temperature rise |
40ºC max |
40ºC max |
40ºC max |
45oC max |
| Dielectric strength (between the case and the terminal) |
1.5KVAC for 1 minute |
1.5KVAC for 1 minute |
1.5KVAC for 1 minute |
1.5KVAC for 1 minute |
| Insulation resistance (between the case and the terminal) |
100 MΩ min |
100 MΩ min |
100 MΩ min |
100 MΩ min |
| operating temperature range |
-10 - +40ºC |
-10 - +40ºC |
-10 - +40ºC |
-10 - +40ºC |
| Attenuation in common mode |
30 dB min (0.15 to 50 MHz) |
20 dB min (0.15 to 0.45 MHz) 30 dB min (0.45 to 50 MHz) |
20 dB min (0.15 to 0.45 MHz) 30 dB min (0.45 to 30 MHz) |
20 dB min (0.15 to 0.45 MHz) 30 dB min (0.45 to 30 MHz) |
| Attenuation in normal mode |
30 dB min (0.15 to 50 MHz) |
20 dB min (0.15 to 0.45 MHz) 40 dB min (0.45 to 50 MHz) |
15 dB min (0.15 to 0.45 MHz) 40 dB min (0.45 to 50 MHz) |
20 dB min (0.15 to 0.45 MHz) 40 dB min (0.45 to 50 MHz) |
Safety standard
|
UL(File No. E119691) |
UL1283 |
UL1283 |
UL1283 |
UL1283 |
CSA(File No. LR88642) |
- |
- |
- |
CSA C22.2 No. 0-M1982 No. 8-M1986 |
(Licence No. R 50030822 0001) |
- |
- |
- |
EN 133200:1999
|