SANRITZ
SiteMap Questions/information Japanese Home
Company OutlineProduct Information
Top > Products Information > EMC Products > Low-Frequency Power Line Noise Filter LNF-5A
Polarizers for LCD
Power supplies
Control units (custom control units)
EMC Products
Power line noise filters FU series
Power line noise filters K series
Power line noise filters E series
Power line noise filters J series
Low-frequency power noise filter LNF-5A
Communication line low-frequency noise filter LF-MJS
Communication line low-frequency noise filter V-MJS
ADSL Adapters
Subscriber Protectors
POLARIZER
EMC Products
 

Low-frequency power noise filter LNF-5A

Questions about products






Uses

• Communication equipment, LAN equipment, OA equipment
Computer peripheral/terminal equipment, measurement instrument, etc.



Features

• The filter can reduce inverter noise at several tens to several hundreds of kHz without the need for grounding.(Principal inverter noise sources: Fluorescent lamps, elevators, UPSs, air-conditioners, washing machines, fans, and other equipment that includes an inverter)
• Smaller, lighter, and less expensive than conventional models.
• An overcurrent protector is used for safety.

LNF series



Protection

When protected equipment is hit with a current that exceeds the rating, the overcurrent protector activates and cuts off the power line.
You can restore the power line by pressing the reset button. However, before you do, you should identify the cause and eliminate it.

Outline Drawing

Outline Drawing
Outline Drawing
Outline Drawing
Unit: mm
Characteristics

• Example of characteristics in common mode
Example of characteristics in common mode

• Example of characteristics in normal mode
Example of characteristics in normal mode

Electrical specifications
Part number LNF-5A
Rated voltage 125 VAC
Rated current 5 A
Supply voltage drop Up to 2 V
Temperature rise 30oC max
Operating temperature range -10 - +40 ºC
Attenuation in common mode 30 dB min (20 kHz to 1 MHz)
Attenuation in normal mode 20 dB min (20 kHz to 1 MHz)
Safety standard Electrical Appliance and Material Safety Law